Verified by manufacturer 2 months ago
SUPALUX® Ceiling, Floors And Roofs - 2500 x 1250 mm
Certifire Certificate
Certificate type
Fire protection to ceilings and protected zones.
Provide fire protection to timber floors and roofs, suspended and self-supporting ceilings.
Promat SUPALUX is an A1 non-combustible calcium silicate board reinforced with selected fibres and fillers which can be used for fire protection of ceilings and protected zones.
New ceiling lining: Timber floor constructions should normally be tested or assessed in accordance with BS 476-21 and are required to satisfy the three failure criteria of loadbearing capacity, integrity and insulation when exposed to fire for below.
Features and benefits:
Color | White Guidance for specification option: Off-white. |
Finish | Sanded |
Material | Calcium silicate Guidance for specification option: A non-combustible calcium silicate board reinforced with selected fibres and fillers. It is formulated without inorganic fibres and does not contain formaldehyde. |
Shape | Square Guidance for specification option: Square profile. |
Length | 2440 mm 2500 mm |
Width | 1220 mm 1250 mm |
Height | 6 mm 9 mm 12 mm 15 mm 20 mm |
Warranty description | Guidance for specification option: Etex Building Performance Limited warrants that our passive fire protection products and component parts, when installed in the building originally designed, built and unaltered in accordance with the conditions and procedures set out in Promat Passive Fire Protection Handbook, this specification document and associated CAD drawings; and any specific technical recommendations made in relation to the above project, shall be durable and free from defects due to faulty manufacturing or factory workmanship. The system must be installed by a 3rd party accredited fire protection contractor, and where included in the specification, solely with proprietary products and components as supplied by Etex Building Performance Limited. The scope of this warranty will be dependent on the application and the environment in which the products are being installed. |
Uniclass | |
CAWS | K11/885 Fire protection board K40/270 Boards P12/310 Boards |
Standard | BS 476-21, BS 476–22. |
Fire rating | To BS EN:13501-1, Class A1.Guidance for specification option: Non-combustible with a reaction to fire Classification of A1 according to BS EN:13501-1. |
Thickness | 20 mm.25 mm. |
Edges | Square. |
Colour | Off-white. |
Certification | Certifire Certificate CF 420, BFTC Report 07/25 (Protected Zone). |
Frame | 'C' channel purlins. 'C' channel purlins, perimeter steel angle. Fire rated exposed grid tee system and galvanised steel wire hangers fixed to beams using steel flange clips. Galvanized wire hanger. Hanger rod. |
Insulation thickness (minimum) | Stone wool insulation thickness. Guidance for specification option: Density varies dependent on floor type selected. |
Fillet strips | Promat SUPALUX® fillet. Guidance for specification option: (Various dimensions dependent on ceiling type selected). |
Inner layer | Promat SUPALUX®. Guidance for specification option: (Various thicknesses dependent on ceiling type selected). |
Face layer | Promat SUPALUX®. Guidance for specification option: (Various thicknesses dependent on ceiling type selected). |
Fasteners | M4 self tapping screws. M4 self tapping screws, M6 expansion bolts. Non-combustible screws or plugs and anchors, Ejot Tec screws, drywall screws. Steel wood screws and nails. Guidance for specification option: (Dependent on ceiling type selected). |
System accessories | PROMASEAL® Intumescent Sealant. |
Fire protection | Protection from above and below. |
Moisture | Humidity up to 85%. Guidance for specification option: Boards can be installed before the building is watertight and are suitable for areas where the humidity is up to 85%. |
Board size | 2500 x 1250 mm. Guidance for specification option: Insert requirements. |
Surface finish | Sanded. |
Type | Protected Zone. Self Supporting Ceilings Membranes (fire from below). Self Supporting Ceilings Membranes (fire from below or above - Integrity only). Self Supporting Ceilings Membranes (fire from below or above - Integrity and Insulation). Suspended Ceilings - Membrane Ceiling (fire from above or below). |