Verified by manufacturer 1 month ago
12 mm sheet
DoP
Certificate type
Naturally dried fibre cement panel with a reflective surface coating.
For walling applications.
A naturally dried fibre cement panel with a reflective surface coating which creates a different return of the light and a shimmering look to the surface. The colours ranges from seven shades of black and grey, each with a slightly green tonality, to two warm white tones and three bronze red-brown tones.
Features and benefits:
Color | Grey Black Ivory Red Green |
Finish | Smooth Reflective |
Material | Fibre cement |
Shape | Rectangle |
Length | 2500 mm 3050 mm |
Width | 1250 mm |
Height | 8 mm 12 mm |
Uniclass | |
CAWS | G20/950 Fascias/ barges/ soffits G20/99 Fascias/ barges/ soffits H20/10 Sheet cladding H92/120 Rainscreen cladding H51/110 Cladding H51/110 Cladding |
Standard | To BS EN 12467. |
Fire rating | To BS EN 13501-1, Class A2-s1, d0. |
Weather resistance | To BS EN 12467, category A. |
Sheet size | |
Nominal thickness | 12 mm. |
Length | 2500 mm.3050 mm.Custom.Guidance for specification option: Special cut individual and free form available. Contact manufacturer for details. |
Width | 1250 mm.Custom.Guidance for specification option: Special cut individual and free form available. Contact manufacturer for details. |
Edges | Square. |
Finish as delivered | Pure acrylate coating (visible face). |
Colour | Granite 4161.Granite 4162.Anthracite 4021.Anthracite 4022.Jade 4051.Crystal 4112.Crystal 4111.Ivory 4091.Ivory 4092.Amber 4071.Amber 4072.Coral 4031.Custom.Guidance for specification option: Custom colours available in NCS, RAL and Pantone shades. Contact manufacturer for details. |
TensileStrength | 8.3–28 MPa. Guidance for specification option: See manufacturer's datasheet for further details. |
Apparent density | 1.65 g/cm³. Guidance for specification option: Minimum 5% fraction. |
CompressiveStrength | 40 MPa. Guidance for specification option: Minimum 5% fraction. |
YoungModulus | 12 000 MPa. Guidance for specification option: Minimum 5% fraction. |
Shrinkage | 1 mm. |
Coefficient of thermal expansion | 1.0E-05 1/K. |
Coefficient of moisture expansion | 0.5 mm. |
ThermalConductivity | 0.56 W/(m·K). |
Density | 26 kg/m². |
MoistureContent | 4% (at 20% relative air humidity). |
Water absorption | 18%. |
Design | Not required. Perforations. Guidance for specification option: Perforations let a lot of natural light into the building and break out of the usual design. Engravings. Guidance for specification option: Geometric shapes, individual patterns, company logos or image motifs can be engraved on individual panels or across multiple panels. |
Material | Fibre cement |