NBS Source
I'm a manufacturer
Compare variants

TCB - Cavity fire barrier for timber frame

Verified by manufacturer 1 year ago

PWTCB50

ARC Building Solutions Limited Variant:
Third party certifications:
  • IFCC

    IFCC

    Certificate type

Cavity barrier for timber frame construction.

Jump to:
+44 (0)113 2529428 Website

Application

  • For fitting within a timber frame cavity.
  • Specified in semi-detached houses, apartments and major projects.
  • Ideally suited for providing a cavity barrier within the external wall cavity, in line with a separating wall or floor, and around window and door openings, as specified in Approved Document B.

Description

Cavity fire barrier designed to be compression fitted within a timber frame cavity. In vertical applications, both flanges are fixed; in horizontal applications, only the top flange should be fixed. The flanges are fixed to the frame using clout nails at 150 mm centres.


The polythene encapsulation offers on-site weather protection but can be cut away without affecting the barrier’s performance.


It restricts the spread of smoke and flames within timber frame cavity walls, as well as minimizing the effect of flanking noise pollution at wall junctions. It is manufactured from low-resin, non-combustible rock fibre mineral wool insulation and is sleeved in polythene for on-site protection.


This product restricts the spread of smoke and flames within the cavity of timber frame walls, while also minimizing the effect of flanking noise pollution. 


Features and benefits:

  • Up to 60 minutes of fire integrity.
  • Horizontal and vertical options.
  • Can be used around window and door openings.
  • Specified in terraced, semi-detached, apartments and major projects.
  • Meets requirements of Robust Detail Part E and Approved Document B.
  • Maximum cavity width available: 150 mm.
  • Easily installed.
  • Third-party certificated by IFC.

General information

Color

White

Yellow

Red

Orange

Material

Rock fibre mineral wool

Length

1200 mm

Width

50 mm

55 mm

60 mm

65 mm

70 mm

Show more

Height

65 mm

75 mm

150 mm

250 mm

Uniclass

Pr_25_80_81_51 Mineral wool fire-stoppingPrimary

CAWS

F30/18 Cavity closers

F30/180 Cavity closers

Specification data - Mineral wool fire-stopping

Material

-

Standard

To BS EN 13162.

Fire performance

To BS EN 13501-1, Euroclass A1.

ThermalConductivity

0.037 W/mK.

Materials

Rock fibre mineral wool.

Colour

White.

Cavity width

50 mm.

Guidance for specification option:

From timber to brickwork.

Dimensions

65 x 250 x 1200 mm.

Third party certifications

IFCC

IFCC

IFCC1727

IFCC

IFCC

IFCC1728

Literature

TCB Data Sheet

TCB Data Sheet