NBS Source
I'm a manufacturer

THERMOLOOK GM/ GF Render System - External Wall Insulation (EWI) System

Verified by manufacturer 7 days ago

PRB Systems Ltd

Render carrier board or External wall insulation (EWI) system based around the THERMOLOOK mineral finish topcoat. Available in a range of finishes and 100 standard colours.

Jump to:
+44 (0) 1242 524 228 Website

Application

Renderboard or External wall insulation, adhesive-fixed.

Description

Render carrier board or External wall insulation (EWI) system based around the THERMOLOOK mineral finish topcoat. Available in a range of finishes and colours.

System build-up (major components):

TH31 external thermal insulation panels, grade EPS70E.

  • Thicknesses from 20 to 120 mm.
  • Acermi certified 17/201/1197.
  • Thermal conductivity: 0.031 W/m·K.
  • Fire behaviour: Euroclass E.

Fondisol F:

  • High-performance fibred base coat and adhesive mortar.
  • BBA approved.

AVN glass reinforcement mesh:

  • Has a high quality synthetic coating on the glass yarn that protects the mesh against alkaline influences from the renders and basecoat materials used.
  • BBA approved.

THERMOLOOK GF/GM mineral topcoat render:

  • Spray machine and hand application.
  • Finishes: fine scraped, medium scraped, roughcast and spray textured.
  • BBA approved.

HYDROFUGE liquid weatherproof coating solution:

  • Helps preserve the original appearance of the substrate.
  • Reduces soiling and the growth of micro-organisms.
  • Water-repellent properties, good surface penetration and coverable.

General information

Color

White

Beige

Grey

Red

Cream

Show more

Finish

Scraped

Roughcast

Textured

Material

Expanded polystyrene (EPS)

Guidance for specification option:

Insulation.

Mineral

Guidance for specification option:

Render.

Render

Shape

Square

Rectangle

Other

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_45_72_28 External wall insulation systemsPrimary

CAWS

M21/210 Rendered external wall insulation systems

M21/20 External wall insulation systems

Specification data - External wall insulation systems

System performance

Guidance for specification option:

Insert requirements.

System manufacturer

PRB Systems Ltd.

Preparation

Guidance for specification option:

Insert requirements.

Insulation

-

Material

TH 31 Exterior thermal insulation, grade EPS70E; grey.

Guidance for specification option:

Insert required thickness; available from 20 to 120 mm in 10 mm increments.

Manufacturer guidance

  • Standard panel size: 1200 x 600 mm.
  • Acermi certified 17/201/1197.
  • Thermal conductivity: 0.031 W/m·K.
  • Fire behaviour: Euroclass E.
  • Thickness tolerance: T2.
  • Tensile strength perpendicular to the sides: TR120.
  • Water vapour transmission: MU30-70.


Consult manufacturer's literature for further details.

Adhesive

FONDISOL F adhesive, white.
FONDISOL F adhesive, grey.

Manufacturer guidance

  • Supplied in 25 kg paper bags or 1.05 tonne pallet (42 x 25 kg bags).
  • BBA certificate UKTA 23/7000.


Consumption:

  • 6–7 m² (3.6–4 kg/m²) for fully bonding the EWI insulation.
  • 9–10 m² (2.5–2.7 kg/m²) for spot bonding the EWI insulation.
  • 4.2–5.4 m² (4.5–5 kg/m²) as a 3–4 mm mesh reinforced base coat.
  • 4.2–5.4 m² (4.5–5 kg/m²) as a 3–4 mm dash receiver.
  • 3–4.5 m² (5–8 kg/m²) as a 4–5 mm mesh reinforced base coat.
  • 2.6–3 m² (8–9 kg/m²) as a 5–6 mm mesh reinforced base coat.

Additional mechanical fixings

Guidance for specification option:

Insert requirements to suit substrate and insulation thickness.

Manufacturer guidance

Insulation boards are to be additionally secured to the substrate using specified thermally broken external wall insulation fixings, typically installed at a ratio of six to seven fixings per square metre or five fixings per insulation board.

The fixing type and length is determined by the substrate and the insulation thickness.

Fire barriers and stops

-

Material

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Fixings

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Beads and trims

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Movement joints

-

Form with

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Sealant

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Accessories

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Render carrier or reinforcement

-

Material

AVN glass reinforcement mesh/ FONDISOL F basecoat (white).
AVN glass reinforcement mesh/ FONDISOL F basecoat (grey).

Manufacturer guidance

AVN glass reinforcement mesh:

  • T Ra M E rating: 3/ 1/ 2/ 2.
  • Material: fibre glass.
  • Coating resin: styrene butadiene copolymer and methacrylate.
  • Colour: white.
  • Supplied in rolls of 50 x 1 m.
  • Consumption: 45 m² per roll at 0.9 m² per m² (including a 100 mm overlap).

FONDISOL F: as Insulation - Adhesive above.

Mesh size

Weft direction: 3.6 mm.
Weave direction: 3.8 mm.
Density: 160 g/m².
Ash content at 625°C: 81%.

Guidance for specification option:

Tolerances:

  • Weft direction: ±0.5 mm.
  • Weave direction: ±0.5 mm.
  • Density: ±5%.
  • Ash content: ±2%.

Fixings

Mesh trowelled into the basecoat.

Render

-

Application

Finish coat.

Material

Vinyl copolymer-based powder, calcic lime, natural hydraulic lime, white cement.

Guidance for specification option:

Other components:

  • Quartz sands.
  • Specific additives.
  • Waterproofing compound, mineral pigments stable in light.

Decorative finish

Fine scraped (GF).
Medium scraped (GM)
Roughcast.
Spray textured.

Colour

Guidance for specification option:

Consult manufacturer's literature for options and insert requirements.

Protective coating

HYDROFUGE liquid weatherproof coating solution.

Guidance for specification option:

  • Colour: clear.
  • Form: liquid.
  • Density: <1 t/m³.
  • pH (alkaline): 11 ±0.5.

Manufacturer guidance

Consumption:

  • Approx. 50–100 m² per 20 litre container applied as one flood coat.
  • Minimum 0.20 L/m² for non-porous substrates.
  • Up to about 0.40 L/m² for porous substrates.

Consumptions may vary depending on the porosity of the substrate to be treated and the application process.

System accessories

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Sustainability data

Material

Expanded polystyrene (EPS)

Guidance for specification option:

Insulation.

Mineral

Guidance for specification option:

Render.

Render

Literature

PRB Systems Product Guide

PRB Systems Product Guide

Thermolook system - Feb 2025

Thermolook system - Feb 2025

CPD materials

Choosing a Render System

Similar products from PRB Systems Ltd

Thermolook EMI - EWI System

Thermolook EMI - EWI System