Verified by manufacturer 3 months ago
50-K-51
BSI Kitemark
Certificate type
EPD
Certificate type
ISO 9001 Quality Management
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
An economical friction-fit system to assemble frames for strong, compact and lightweight non load‑bearing partition.
Sectors:
TRADELINE C Stud systems are lightweight, non-load-bearing, friction-fit systems.
They can be used within all sectors, from simple subdivision of space to providing high levels of acoustic, fire and duty performance whilst achieving heights up to 8.7m (10.2m using I stud)
Features and benefits:
Structural performance:
Fire performance:
Acoustic performance:
Installing framing for partitions:
Length | Bespoke |
Width | 77 mm 82 mm 97 mm 102 mm 112 mm |
Height | Bespoke |
Uniclass | |
CAWS | K10/30 Metal stud K10/125 Metal stud partition system |
Product range |
Framing | Tradeline 'C' stud, 50 mm. |
Linings | |
Outer layers | Knauf Wallboard, 12.5 mm. |
Fasteners | Tradeline Drywall Screws. |
Joint treatment | Tradeline Joint Tape.Tradeline Paper Joint Tape.Tradeline Light Weight All Purpose Joint Compound.Tradeline Metal Corner Tape.Tradeline Flexible Metal Corner Tape.Tradeline Scrim Tape.Tradeline Drywall Self-Adhesive Joint Tape. |
System accessories | Tradeline Acoustic Intumescent Sealant.Tradeline PB24 Partition Brace.Tradeline FS24 Flat Bracing Strip. |
Fire resistance | To BS 476:1987:Part 22, 30/ 30 minutes (Integrity/ Insulation) |
Partition height | Guidance for specification option: Insert requirement based on centres specified.
Calculated based on a limiting deflection of L/240 at 200 Pascals. |
Nominal thickness | 77 mm. Manufacturer guidanceOptimum system thickness. Note that if a greater partition thickness is required, this may improve the sound reduction index (Rw) - consult manufacturer for details. |
Centres | 600 mm. Guidance for specification option: Allows for greater maximum partition heights. 400 mm. Guidance for specification option: Allows for greater maximum partition heights. 300 mm. Guidance for specification option: Standard. |
StrengthGrade | Medium duty. |
Head/ Floor channel | Tradeline Standard Track. Guidance for specification option: Used for partition heights under 4 m. Available in 50, 52, 62 or 72 mm wide. 25 mm flange. Tradeline 32 mm Leg Track. Guidance for specification option: Used for partition heights under 4 m. Available in 52, 62, 72, 94 or 148 mm wide. 32 mm flange. Tradeline Deep Track. Guidance for specification option: Used for partition heights between 4 m and 8 m. Can be used as a head track where a deflection head of up to 30 mm is needed. Available in 52, 62, 72, 94 or 148 mm wide. 50 mm flange. Tradeline Extra Deep Track. Guidance for specification option: Used for partition heights between 8 m and 10.2 m. Can be used as a head track where a deflection head of up to 45 mm is needed. Available in 72, 94 or 148 mm wide. 70 mm flange. |
BSI Kitemark
BIM Level 2 Kitemark - For Design and Construction Phase
BSI Kitemark
BSI Kitemark™ for BIM Objects
EPD
Environmental Product Declaration EPD - Drylining
ISO 9001 Quality Management
ISO 9001:2015 Quality Management System
UK Conformity Assessed (UKCA)
UKCA Declarations of Performance - Drylining