Verified by manufacturer 1 day ago
NE: Standard panel
EPD
Certificate type
Top hung movable acoustic wall.
To limit noise transmission between rooms.
Sliding stacking panel partition.
Features and benefits:
Color | Manufacturer guidanceStandard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements |
Finish | Manufacturer guidanceStandard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements |
Material | Aluminium Glass |
Shape | Rectangle |
Length | Bespoke Manufacturer guidance1200mm wide x 20000mm high maximum panel dimension |
Width | Bespoke Manufacturer guidance1200mm wide x 20000mm high maximum panel dimension |
Warranty description | Two year |
Uniclass | |
CAWS | K30/76 Glazing for relocatable partitions K30/480 Glazing for relocatable partitions L20/545 Sliding stacking panel partitions |
SKU Code | 100 |
Performance | Up to 60 dB to EN ISO 140-3. Guidance for specification option:
|
Operation | E: Fully electric. Guidance for specification option:
M: Manual. Guidance for specification option:
SE: Semi-electric. Guidance for specification option:
|
Dimensions (nominal) | |
Panel (average) | |
Width | Guidance for specification option: Up to 1230 mm (maximum). Wider panels possible to special order; insert requirements. |
Height | Guidance for specification option: Minimum: 1.5 m up to 15 m *maximum); insert requirements. |
Thickness | 19 mm. |
Track system | |
Wall jamb and abutments | Finished to match panels as standard. Manufacturer guidance
|
Panels | |
Construction | Internal bracket frame with double skin cladding of 19 mm thick, three layer, high density chipboard. |
Finish as delivered | Back painted glass. Client supplied fully finished boards. Guidance for specification option: Insert details as required. Factory spray paint to RAL colour. Guidance for specification option: Insert requirement. High pressure laminate. Lacquered steel sheet to RAL colour. Guidance for specification option: Insert requirement. Magnetic back painted glass. Magnetic whiteboard laminate. Perforated sound absorbent board. Guidance for specification option: Perforation specification by specifier; insert details as required. Priming sheet ready for ‘on site’ decoration by others. Guidance for specification option: Insert details as required. Slotted sound absorbent board. Guidance for specification option: Slot specification by specifier; insert details as required. Standard laminate. Stretch fabric system. Guidance for specification option: Thickness and fabric specification by specifier; insert details as required. Veneer. Guidance for specification option: Insert details of species type and cut. Whiteboard laminate. Manufacturer guidanceWhere panel type varies within the partition assembly, insert identifiers for panels after each selection. |
Panel Type | Standard panel. |
Track profile | Manufacturer guidance
|
Track layout | TL 1 ‘E’ system. Guidance for specification option:
TL 2 ‘Za’ system. Guidance for specification option:
TL 3 ‘Zb’ system. Guidance for specification option:
TL 4 ‘Z’ system. Guidance for specification option:
TL 5 ‘K’ system. Guidance for specification option:
Manufacturer guidancePlease note: If Type TL1 'E' track is specified then Rw 58dB (laboratory tested) sound reduction and Rw 60dB (laboratory tested) sound reduction is not suitable. |
Fire performance | Class 1 to BS 476. Guidance for specification option: Available with optional finish from standard range rated Class 1 Surface Spread of Flame, when tested to BS 476. Class 0 to Approved Document M. Guidance for specification option: In accordance with Building Regulation (E&W) Approved Document B. Manufacturer guidance
|
Partition assembly | Refer to manufacturer drawing (SL – 101, SL – 102 and SL – 103), for disposition of specified elements. |
Panel vertical edge type | Concealed. Exposed. |
Bunching | Bi–parting. Double stack. Single stack. |
Acoustic insulation | Rw 37 dB. Rw 41 dB. Rw 43 dB. Rw 44 dB. Rw 45 dB. Manufacturer guidancePlease note: If Rw 58dB or Rw 60dB is specified then Type TL1 'E' track single point suspension is not suitable. |
FireRating | Not fire rated. Guidance for specification option: Standard. 30 minute fire rated. 60 minute fire rated (no pass door). |
Ceiling angle trim | None. Exposed 20 mm from underside of ceiling. Guidance for specification option: Single point suspension only. Flush with underside of ceiling. Guidance for specification option: Two point suspension only. |
Track finish | White. Guidance for specification option: As standard, spray painted. RAL. Guidance for specification option: Spray painted, special order; insert requirement. Powder-coated aluminium, RAL. Guidance for specification option: Insert requirement. Satin anodized aluminium. Guidance for specification option: Standard. |
Country of material origin | Manufacturer guidanceGermany, Holland or Sweden |
Country of product manufacture | Manufacturer guidanceGermany, Holland or Sweden |
Material | Aluminium Glass |
Recyclability | Metal parts can be separated and directed to material recycling. Theoretically, particle board can also be recycled by directing the panels to new production |
Certified