Verified by manufacturer 18 days ago
Insulated roof and wall breather underlay membrane.
An insulated roof and wall underlay membrane that is airtight and ventilated. When used in conjunction with standard insulation products, the product enhances U-values through an integrated insulation layer that is laminated to a high emissivity surface. Manufactured using hydrophobic and self-extinguishing polyester fibre created from recycled material.
Features and benefits:
Color | Silver White |
Finish | Metallic Reflective |
Material | Polyethylene Guidance for specification option: Non-woven and recycled PE insulation. Polyester fibre (PET) Guidance for specification option: Hydrophobic and self-extinguishing, created from recycled material. |
Shape | Other |
Length | 10000 mm |
Width | 1400 mm |
Height | 3.7 mm Manufacturer guidanceDepth. |
Warranty description | Ten year |
Uniclass | |
CAWS | H20/150 Sheet cladding (attached to metal support systems) H20/155 Sheet cladding (attached to timber battens) H21/110 Vertical timber weatherboarding H21/111 Horizontal timber weatherboarding H21/115 Vertical timber weatherboarding H21/116 Horizontal timber weatherboarding H21/130 Breather membrane H21/20 Breather membrane H30/110 Fibre cement H30/120 Fibre cement H30/350 Breather membrane H30/50 Breather membrane H31/280 Breather membrane H31/55 Breather membrane H60/105 Clay roof tiling H60/110 Clay roof tiling with counterbattens H60/120 Concrete roof tiling H60/125 Concrete roof tiling with counterbattens H60/145 Clay vertical tiling H60/155 Concrete vertical tiling H61/105 Roof slating H61/110 Roof slating with counterbattens H61/120 Vertical slating H62/105 Roof slating H62/110 Roof slating with counterbattens H62/120 Vertical slating H62/125 Roof slating H62/130 Roof slating with counterbattens H62/140 Vertical slating H62/145 Roof slating H62/150 Roof slating with counterbattens H64/110 Wood shingle/ shake roofing H64/120 Wood shingle/ shake roofing with counterbattens H64/130 Vertical wood shingle/ shakes H65/105 Clay roof tiling H65/110 Clay roof tiling with counterbattens H65/115 Concrete roof tiling H65/120 Concrete roof tiling with counterbattens H65/125 Reconstituted slate roof tiling H65/130 Reconstituted slate roof tiling with counterbattens H65/135 Ceramic slate roof tiling H65/140 Ceramic slate roof tiling with counterbattens H67/110 Metal roof tiling H67/120 Metal roof tiling with counterbattens H67/130 Metal vertical tiling H92/120 Rainscreen cladding K21/111 Wood floating floor M30/265 Building paper P10/320 Breather membrane P10/65 Breather membrane |
Product range |
Standard | To BS EN 13859-1.Guidance for specification option: Roofs. To BS EN 13859-2.Guidance for specification option: Walls. |
Material | Polyethylene.Polyester fibre (PET).Guidance for specification option: Hydrophobic and self-extinguishing, created from recycled material. |
Form | Non-woven. |
Third-party certification | CE marked to EN 13859-1 and -2. |
Weight (minimum) | 730 g/m². |
Reflective face | 82%. |
Surface area per roll | 14 m². |
Operating temperature range | -40 to 80°C. |
Fire resistance classification | E. |
Thermal core resistance (R-value) | 1 m²K/W. |
ThermalConductivity | To EN 12667, 0.0366 W/m·K. |
Thermal resistance together with one unventilated air gap, wall (R-value) | 1.47 m²K/W. |
Resistance to water penetration | W1 to EN 1928. |
Water vapour transmission | 380 g/m². |
Tensile property, longitudinal | 220–360 N/50mm. |
Tensile property, traversal | To EN 12311-1, 150–275 N/50mm. |
Resistance to tearing, longitudinal | 120–230 N. |
Resistance to tearing, traversal | To EN 12310-1, 175–280 N. |
Standard deviation (Sd) value | To EN 12572:2003, <0.061 m (±0.01). |
Emissivity | 0.18. |
Resistance to air penetration | To EN 12114, 0.000 m³/m³.h.50.pa. |
Tape | Novia Breather Membrane Lap Tape. |
Country of material origin | Belgium |
Country of product manufacture | Belgium |
Recyclability | Recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidanceHydrophobic and self-extinguishing polyester fibre. |