NBS Source
I'm a manufacturer

Halfen HIT Balcony Connector for Post Tensioning Applications - High Performance Structural Connection

Verified by manufacturer 4 months ago

Leviat

High performance structural connection system which can be used to join post-tensioned concrete balconies to a post-tensioned concrete slab.

Jump to:
+44 (0) 114 275 5224 Website

Application

Can be used to join post tensioned concrete balconies to a post tensioned concrete slab. Suitable for use with all types of proprietary bonded and unbonded post tensioning systems.

Description

High performance structural connection system which can be used to join post tensioned concrete balconies to a post tensioned concrete slab.


Features and benefits:

  • Suitable for use with all types of proprietary bonded and unbonded post tensioning systems.
  • Incorporates the Halfen HIT Structural Thermal Break, allows balconies to be cast together with the main slab and then simultaneously tensioned.
  • Transfers tension and compression forces in addition to bending moments and shear forces.
  • Two insulation thicknesses available (80 and 120 mm) offering exceptional thermal efficiency.
  • Fully integrated REI 120 fire protection.
  • All support elements are sufficiently secured in a sturdy housing to ensure safe delivery, transport and easy on-site handling.
  • Symmetrical connector simplifies installation.
  • Enabled by UKTA-0836-22/6015 - Annex D.

General information

Color

Black

Silver

Material

Stainless steel

Steel

Length

250 mm

500 mm

1000 mm

Width

80 mm

120 mm

Manufacturer guidance

Insulation thickness.

Height

Bespoke

Guidance for specification option:

Dependent on concrete slab thickness.

Uniclass

Pr_35_90_15_88 Thermal break shear load connectorsPrimary

CAWS

E42/335 Shear load connectors

E42/335 Shear Load Connectors

E42/110 Accessories specified elsewhere

E42/110 Accessories specified elsewhere

Specification data - Thermal break shear load connectors

Certification

EOTA: ETA-18/0189 including fire protection, thermal values and noise reduction DoP no. H10-18/0189.; BBA UKTA-0836-22/6015.

Material

Steel/ stainless steel.

Guidance for specification option:

Tension bars:

  • Flash butt-welded bar connection consisting of a combination of two reinforcing steel bars (B500 according to DIN 488) and a stainless steel bar of strength class S 690 or stainless steel B500NR.

Shear bars:

  • Stainless steel bar of strength B500NR or flash butt-welded connection, consisting of a combination of stainless steel bar B500NR and reinforcing steel bars B500B.

Compression shear bearings:

  • High-performance mortar with increased compressive and tensile strength as well as optimized thermal performance.

Casing:

  • Plastic according to EN ISO 1163.

Connecting components:

  • Suitable for concrete strengths ≥C20/25.

On-site reinforcement:

  • Reinforcement steel B500B/B500C.

Thickness of structural deck

Guidance for specification option:

Insert requirements.

Insulation

HIT-HP (80 mm thick).

HIT-SP (120 mm thick).

Manufacturer guidance

Mineral wool (WLG 035) of Building Material Class A1, non-flammable insulation according to DIN 4102-14 or Euro Class A1 according to EN 13501-1.

Consult manufacturer for further details.

Size (h x w)

Guidance for specification option:

Insert requirements.

  • Height: Standard heights from 160 to 350 mm; Up to 500 mm available on request.
  • Width: 100 mm or 150 mm.

Manufacturer guidance

Dimensions (w x h) of the HIT transition piece.

Offset

Guidance for specification option:

Insert requirements, 10–105 mm, depending on the height of the HIT element.

Manufacturer guidance

Vertical offset between the HIT centre line and the tendon centre line.

Bracket

-

Manufacturer guidance

  • Bracket size varies, refer product reference code and manufacturer requirements.
  • Recommended fixing bolt clearance hole diameter in balcony steelwork varies, refer product reference code and manufacturer requirements.

Anchor spacing

Guidance for specification option:

Consult manufacturer for details and insert requirements.

Fixing

Guidance for specification option:

Consult manufacturer for details and insert requirements.

Sustainability data

Material

Stainless steel

Steel

Literature

Halfen HIT Insulated Balcony Connector System

Halfen HIT Insulated Balcony Connector System

Case studies

Bayside, Worthing

Bayside, Worthing

Similar products from Leviat

Ancon Stainless Steel To Concrete Balcony Connectors

Ancon Stainless Steel To Concrete Balcony Connectors

Ancon Steel To Concrete Balcony Connectors

Ancon Steel To Concrete Balcony Connectors