Verified by manufacturer 27 days ago
Level 2
Low profile security rooflight for flat roofs with thermally decoupled liner. Certified Secured By Design by the LPCB.
Suitable for all nominally flat roof constructions in accordance with certified installation detail (Drawing Number PS_100INST).
The widest range of Secured by Design accredited rooflights that are tried and tested to give peace of mind that security building regulations are met.
Features and benefits:
Color | Black Guidance for specification option: RAL9005. Grey Guidance for specification option: Light Grey (BS00A09), Dark Grey (BS00A13). White Guidance for specification option: RAL9010. Other Guidance for specification option: As per manufacturer and includes BS, RAL and other special colours to match roof covering available on request. |
Finish | Powder-coated |
Material | Glass Stainless steel |
Shape | Square Rectangle |
Warranty description | One year Guidance for specification option: On ancillary items. Five year Guidance for specification option: On glass. Ten year Guidance for specification option: On frames upon the rooflights being registered for free online via the manufacturer website. |
Uniclass | |
CAWS | L10/45 Rooflights L10/460 Rooflights |
Product range |
Form | Flat. |
Size | Guidance for specification option: Insert requirements:
|
Frame | |
Material | Stainless steel. |
Finish | |
Coating | Polyester powder coating. |
Colour | Black (RAL 9005).Dark Grey (BS 00A13).Light Grey (BS 00A09).White (RAL 9010).Any BS.Guidance for specification option: Insert requirements. Any RAL.Guidance for specification option: Insert requirements. Manufacturer guidanceFour standard Paint colours are available with matching glazing beading and Thermoliner®. |
Glazing or infill | |
Type | Insulating glass units. |
Construction | 6 mm Solar Low 'E' Toughened Outer, 12 mm Cavity, 18 mm TSG DCT18 (glass-poly-glass) Inner.Guidance for specification option: SR2 glazing only. 6 mm Solar Low 'E' Toughened Outer, 12 mm Cavity, 20 mm TSG DCT20 (glass-poly-glass) Inner.Guidance for specification option: SR3 glazing only. |
Integral kerb | Insulated.Guidance for specification option: Insulated kerb to be formed on site as per certified installation details. |
Operation | |
Type | Fixed shut. |
Accessories | Not required.Coated stainless intruder security bars. |
Standard | To BS EN1279-2. |
Third-party certification | Loss Prevention Standard: 1175 issue 7 Level 2 (without bars), Loss Prevention Standard: 1175 issue 7 Level 3 (with bars), KM 93754, BSI Kitemark and QA Certificate. |