Verified by manufacturer 2 months ago
Stylish, contemporary and durable internal steel single doorset with up to four hours' fire resistance.
For internal and external applications in all forms of masonry, concrete and flexible stud wall (coldwall style) constructions. When using timber or steel stud walls, the client must ensure they have adequate evidence that the wall can support steel fire doors under fire conditions. 120 and 240 fire rated stud wall constructions should have the walls’ reveal face protected by a fire resting board to protect the wall construction.
Single leaf, single swing doorset made from corrosion-resistant Magnelis© sheets and rigid core.
Features and benefits:
Finish | Unfinished Woodgrain Powder-coated Guidance for specification option: Polyester powder coated. |
Material | Steel Guidance for specification option: Corrosion resistant Magnelis© sheets and rigid core. |
Shape | Rectangle |
Width | 1370 mm Guidance for specification option: Maximum. |
Height | 2830 mm Guidance for specification option: Maximum. |
Uniclass | |
CAWS | L20/480 Doorsets L20/55 Doorsets |
Configuration | Single leaf, latched.Guidance for specification option: Available up to 1370 x 2830 mm (w x h) or 3.56 m². Single leaf, unlatched.Guidance for specification option: Available up to 1300 x 2500 mm (w x h) or 2.96 m². |
Doorset size | 1370 x 2830 mm.Guidance for specification option: Maximum. |
Performance | |
Fire resistance | |
Integrity | To BS 476-20/2 and BS EN 1634, four hours. |
Frame | |
Material | Magnelis©.Guidance for specification option: 1.5 mm thick Magnelis© sheets, screw and tab construction. |
Threshold | Not required.5 mm aluminium driveable.Guidance for specification option: DDA compliant. 15 mm aluminium.Guidance for specification option: DDA compliant. 15 mm steel pressed rebated.Guidance for specification option: Special order. |
Finish | |
Coating | Guidance for specification option: [-] - Insert requirements. |
Colour | Guidance for specification option: [-] - Insert requirements. |
Door leaf | |
Thickness | 54 mm. |
Core | Mineral wool.Self-supporting resin-impregnated honeycomb. |
Material | Magnelis©.Guidance for specification option: Non-welded, manufactured from two 1.2 mm thick corrosion resistant Magnelis© sheets. |
Glazing | |
Type | Not required.8 mm thick Firelite Safety.Special order. |
Finish | |
Coating | 8 mm thick Firelite Safety.Guidance for specification option: Insert colour requirement. Polyester powder coated, standard colour range.Guidance for specification option: Insert colour requirement. PVC laminate, standard range.Guidance for specification option: Insert colour requirement. Stainless steel, brushed.Stainless steel, patterned.Stainless steel, polished.Unfinished.Guidance for specification option: For site finishing. Woodgrain PVC laminate. |
Hardware | Guidance for specification option: [-] - Insert requirements. |
Accessories | Guidance for specification option: [-] - Insert requirements. |
Execution | Installing hardware. |
Product Reference | INNA-DOR 240 Single |
Profile | Type A. Guidance for specification option: 100 mm depth. Type B. Guidance for specification option: 95 mm depth. Type C. Guidance for specification option: 95 mm depth. Type D. Guidance for specification option: 145 mm depth. Manufacturer guidanceFrame profile. |
Type | Not required. 254 x 254 mm. 254 x 559 mm. 254 x 762 mm. 254 x 1219 mm. Manufacturer guidanceVision panels type. |
Glazing | Not required. 8 mm thick Firelite Safety. Special order. Guidance for specification option: Insert requirement, contact manufacturer for information. Manufacturer guidanceVision panels. |
Type | Not required. 457 x 457 mm lower. Guidance for specification option: BS 476 and BS EN1634 compliant. 457 x 457 mm upper. Guidance for specification option: BS 476 compliant. 457 x 457 mm lower and upper. 610 x 610 mm lower. Guidance for specification option: BS EN1634 compliant. Manufacturer guidanceLouvre panels. |
Blade material | Not required. Galvanized steel, 18 g. Guidance for specification option: Standard. Stainless steel, grade 1.4301 (304). Stainless steel, grade 1.4401 (316). Manufacturer guidanceLouvre panels. |
Configuration | Not required. As drawing. Guidance for specification option: Insert reference. As schedule. Guidance for specification option: Insert reference. Manufacturer guidanceSide over panels. |
Type | Not required. Fixed. Hinged. Manufacturer guidanceSide over panels. |
Construction | Not required. Glazed, 8 mm thick Firelite Safety. Louvred. Solid. Manufacturer guidanceSide over panels. |
Contains Red List materials | Yes Guidance for specification option: Wood grain laminate contain PVC. |
Country of material origin | United Kingdom |
Recyclability | 98% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidanceNew materials only. |
GLAS-DOR Doorsets - Fire rated steel doorsets
INTEGRA 4000 Series - Fire Rated Riser Doors with Adjustable Frame
INTEGRA 4000 Series - Non Fire Rated Riser Doors
INTEGRA 4000 Series - UL Fire Rated Riser Doors
VEGA 1500 FR Series Riser Doors with Adjustable Frame
VEGA 1500 Series Riser Doors - Non Fire Rated
VISION 8000 - Fire Rated Riser Door
VISION 8000 - Non Fire Rated Riser Door
VISION 8000 EI60 Series INSULATED RISER DOORS