NBS Source
I'm a manufacturer

Profiles XL Cold Deck System

Verified by manufacturer 15 days ago

BMI Group UK Ltd

A two layer, high performance, SBS modified bitumen, torch-on flat roofing system.

Jump to:
0370 560 1000 Website

Application

Suitable for direct application to non-combustible substrates only, such as concrete/ screed, or in overlay situations onto existing asphalt/ built-up roof (BUR) substrates. Specify Profiles T.A. System for combustible substrates such as plywood or OSB.


Preparation:

  • Consult manufacturer for details of the preparation and priming of the intended roof structure and substrate, and for details of the requirements for preparation layers, venting layers, nailing layers and taping strips.

Description

A two layer system incorporating a range of styrene butadiene styrene (SBS) modified elastomeric bitumen membranes and accessories. Profiles Systems incorporate a ‘striped’ pattern. This advanced vapour release technology has been designed to dissipate moisture vapour that may be trapped in the roofing system. When this trapped moisture warms, it can form pressure pockets within the system. Low melt bitumen needs a minimal application of flame to activate its fast adhesive properties.


Features and benefits:

  • High performance.
  • Offer a design and specification service (recommended that they are consulted early on in the design process).

General information

Color

Blue

Grey

Green

Brown

Material

Bitumen

Guidance for specification option:

Styrene butadiene styrene (SBS) modified.

Shape

Other

Uniclass

Ss_30_40_30_70 Reinforced bitumen membrane cold roof covering systemsPrimary

CAWS

J41/130 Built-up reinforced bitumen membrane cold deck roof covering

Specification data - Reinforced bitumen membrane cold roof covering systems

Classification data

Waterproof covering

-

Top layer

-

Type

Profiles XL.

System accessories

None.
Icopal GRP Edge Trims.
Icopal Roofgard Outlet.
Icopal Roofgard Parapet Outlet.
Icopal Roofgard Cable and Tube Duct.
Icopal Roofgard Cowled Telescopic Vent.
Icopal Roofgard Lightning Conductor Pads.

Primer

Icopal S.F. Bitumen Primer.

Guidance for specification option:

Solvent-free bituminous primer.

Icopal Siplast Bitumen Primer.

Guidance for specification option:

Quick-drying primer for torch-applied membranes.

Underlay

Profiles Vent XL.

Guidance for specification option:

Torch-applied membrane with stripes on underside to provide partial bond.

Colour

Green.
Brown.
Noxite.
Blue-grey.

Underlay

Icopal T.A. Detailing Underlay.

Guidance for specification option:

Thermically-activated, self-adhesive membrane for combustible details.

Profiles XL Sand.

Guidance for specification option:

4 mm torch-applied membrane.

Capsheet

FireSmart T.A. Detailing Capsheet.

Guidance for specification option:

Thermically-activated capsheet for combustible details.

Profiles XL Mineral.

Guidance for specification option:

Torch-applied capsheet.

Similar products from BMI Group UK Ltd

Profiles T.A. Cold Roofing System

Profiles T.A. Cold Roofing System

Profiles XL FireSmart Plus System - Cold Roof / Heated / Full Bond - System Number 17

Profiles XL FireSmart Plus System - Cold Roof / Heated / Full Bond - System Number 17

Profiles XL FireSmart Plus System - Cold Roof / Heated / Partial Bond - System Number 15

Profiles XL FireSmart Plus System - Cold Roof / Heated / Partial Bond - System Number 15

Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Full Bond  - System Number 16

Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Full Bond - System Number 16

Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Partial Bond  - System Number 14

Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Partial Bond - System Number 14

ThermoSolo Roofing System

Total Torch Inverted Cold Deck Roofing System

Total Torch Inverted Cold Deck Roofing System