Verified by manufacturer 15 days ago
A two layer, high performance, SBS modified bitumen, torch-on flat roofing system.
Suitable for direct application to non-combustible substrates only, such as concrete/ screed, or in overlay situations onto existing asphalt/ built-up roof (BUR) substrates. Specify Profiles T.A. System for combustible substrates such as plywood or OSB.
Preparation:
A two layer system incorporating a range of styrene butadiene styrene (SBS) modified elastomeric bitumen membranes and accessories. Profiles Systems incorporate a ‘striped’ pattern. This advanced vapour release technology has been designed to dissipate moisture vapour that may be trapped in the roofing system. When this trapped moisture warms, it can form pressure pockets within the system. Low melt bitumen needs a minimal application of flame to activate its fast adhesive properties.
Features and benefits:
Color | Blue Grey Green Brown |
Material | Bitumen Guidance for specification option: Styrene butadiene styrene (SBS) modified. |
Shape | Other |
Uniclass | |
CAWS | J41/130 Built-up reinforced bitumen membrane cold deck roof covering |
Classification data | |
Waterproof covering | |
Top layer | |
Type | Profiles XL. |
System accessories | None. Icopal GRP Edge Trims. Icopal Roofgard Outlet. Icopal Roofgard Parapet Outlet. Icopal Roofgard Cable and Tube Duct. Icopal Roofgard Cowled Telescopic Vent. Icopal Roofgard Lightning Conductor Pads. |
Primer | Icopal S.F. Bitumen Primer. Guidance for specification option: Solvent-free bituminous primer. Icopal Siplast Bitumen Primer. Guidance for specification option: Quick-drying primer for torch-applied membranes. |
Underlay | Profiles Vent XL. Guidance for specification option: Torch-applied membrane with stripes on underside to provide partial bond. |
Colour | Green. Brown. Noxite. Blue-grey. |
Underlay | Icopal T.A. Detailing Underlay. Guidance for specification option: Thermically-activated, self-adhesive membrane for combustible details. Profiles XL Sand. Guidance for specification option: 4 mm torch-applied membrane. |
Capsheet | FireSmart T.A. Detailing Capsheet. Guidance for specification option: Thermically-activated capsheet for combustible details. Profiles XL Mineral. Guidance for specification option: Torch-applied capsheet. |
Profiles T.A. Cold Roofing System
Profiles XL FireSmart Plus System - Cold Roof / Heated / Full Bond - System Number 17
Profiles XL FireSmart Plus System - Cold Roof / Heated / Partial Bond - System Number 15
Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Full Bond - System Number 16
Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Partial Bond - System Number 14
ThermoSolo Roofing System
Total Torch Inverted Cold Deck Roofing System