NBS Source
I'm a manufacturer

Total Torch Inverted Cold Deck Roofing System

Verified by manufacturer 15 days ago

BMI Group UK Ltd

A two layer, cold deck roofing system.

Jump to:
0370 560 1000 Website

Application

Suitable for direct application to non-combustible substrates, such as concrete/ screed, or in overlay situations onto existing asphalt/ built-up roof (BUR) substrates.


Preparation:

  • Consult manufacturer for details of the preparation and priming of the intended roof structure and substrate, and for details of the requirements for preparation layers, venting layers, nailing layers and taping strips.

Description

A two layer, cold deck roofing system, incorporating a range of styrene butadiene styrene (SBS) modified, elastomeric bitumen membranes and accessories. The membranes incorporate a ‘striped’ pattern. This advanced vapour release technology has been designed to dissipate any moisture vapour that may be trapped in the roofing system. When the trapped moisture warms up, it can form pressure pockets within the system. The Total Torch Vapour Dispersion Layer has been engineered to neutralize this potential problem. Low melt bitumen needs a minimal application of flame to activate its fast adhesive properties.

General information

Color

Blue

Grey

Black

Green

Brown

Manufacturer guidance

Top layer/ Capsheet colour. To match field sheet, consult manufacturer for details.

Material

Bitumen

Guidance for specification option:

Styrene butadiene styrene (SBS) modified.

Shape

Other

Uniclass

Ss_30_40_30_70 Reinforced bitumen membrane cold roof covering systemsPrimary

CAWS

J41/130 Built-up reinforced bitumen membrane cold deck roof covering

Specification data - Reinforced bitumen membrane cold roof covering systems

Classification data

Waterproof covering

-

Top layer

-

Type

Thermaweld Capsheet.
Tecnatorch SBS Capsheet.
Total Torch SBS Capsheet.

Manufacturer guidance

Torch-applied capsheet.

System accessories

None.
Icopal GRP Edge Trims.
Icopal Roofgard Outlet.
Icopal Roofgard Parapet Outlet.
Icopal Lightning Conductor Pads.
Icopal Roofgard Cable and Tube Duct.
Icopal Roofgard Cowled Telescopic Vent.

Primer

Icopal Siplast Bitumen Primer.

Guidance for specification option:

Quick-drying primer for torch-applied membranes.

Underlay

Total Torch Vapour Dispersion Layer.

Guidance for specification option:

Torch-applied underlay with stripes on underside to provide partial bond.

Colour

Green.
Brown.
Charcoal.
Blue-grey.

Manufacturer guidance

Top layer/ Capsheet colour. To match field sheet, consult manufacturer for details.

Underlay

Premium SBS Torch On Underlay.

Guidance for specification option:

2 mm polyester reinforced torch-applied underlay.

Tecnatorch SBS Sand.

Guidance for specification option:

4 mm torch-applied membrane.

TorchSafe Detailing Underlay.

Guidance for specification option:

3 mm self-adhesive underlay.

Capsheet

FireSmart T.A. Detailing Capsheet.

Guidance for specification option:

Self-adhesive capsheet.

Tecnatorch SBS Capsheet.

Guidance for specification option:

Torch-applied capsheet.

Thermaweld Capsheet.

Guidance for specification option:

Torch-applied capsheet.

Total Torch SBS Capsheet.

Guidance for specification option:

Torch-applied capsheet.

Similar products from BMI Group UK Ltd

Profiles T.A. Cold Roofing System

Profiles T.A. Cold Roofing System

Profiles XL Cold Deck System

Profiles XL Cold Deck System

Profiles XL FireSmart Plus System - Cold Roof / Heated / Full Bond - System Number 17

Profiles XL FireSmart Plus System - Cold Roof / Heated / Full Bond - System Number 17

Profiles XL FireSmart Plus System - Cold Roof / Heated / Partial Bond - System Number 15

Profiles XL FireSmart Plus System - Cold Roof / Heated / Partial Bond - System Number 15

Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Full Bond  - System Number 16

Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Full Bond - System Number 16

Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Partial Bond  - System Number 14

Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Partial Bond - System Number 14

ThermoSolo Roofing System