Application

For protecting painted wood and wood-based boards on walls and ceilings.

Description

Thermoguard Smoke and Flame Retardant Dualcoat is a fire retardant topcoat and maintenance paint that can be used as part of a flame and fire retardant system for timber surfaces protected with Thermoguard Timbercoat internally and externally.


Features and benefits:

  • Available in pack sizes of 20 m² and 40 m².
  • Compliant with BS EN 13501, B-s1,d0 standards, providing protection against toxic smoke, flaming droplets and flamespread/ insulation.
  • Can be used on suitable external timber cladding. Best to apply to all sides. If not practical, seal void with fire rated foam and acrylic intumescent mastic.
  • Can be used as part of a system to achieve 30 or 60 minutes fire resistance.
  • Insulating Basecoat expands in a fire to create a resilient insulating barrier.
  • Dualcoat Smoke and Flame Retardant emits a safe fire-damping vapour in a fire to control flame spread and suppress smoke.
  • Dualcoat SFR’s polyurethane hardened acrylic “cross-links” during the drying process to form a smoother, harder, more cleanable surface than typical wall paints and help eliminate the microscopic pockets that host bacteria which prevent effective cleaning. 
  • UKAS and EOTA approved over 10, 14 and 20 coats of all wall paint types used on buildings since vinyl, acrylic, oil based, anti-graffiti, with or without wallpaper and the flame retardant paint that emits toxic antimony gas. 


Application:

  • Insulating basecoats must be clean and fully hard dry. Stir well before use.
  • Brush and roller applied via a woven short pile roller sleeve or synthetic brush at rate stated on can or spray applied using a pressure pot and gun conventional with hand-portable compressor. 
  • Ensure coverage is applied as per can instructions.

General information

Color

White

Other

Guidance for specification option:

NCS, RAL, BS 4800, BS 381 and Thermoguard Select available on request.

Finish

Matt

Eggshell

Satin

Material

Water-based

Shape

Formless

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_35_31_68_29 Flame-retardant coatingsPrimary

CAWS

M60/172 Flame-retardant coating system

M60/18 Special coating

M60/195 Special coating

M60/175 Protective coating

M60/19 Flame-retardant coatings

Specification data - Flame-retardant coatings

Reaction to fire rating (indicative)

To BS EN 13501, B-s1,d0.

Solvent

Water-based.

VOC content (maximum)

16 g/L.

Colour

White.

Other.

Guidance for specification option:

NCS, RAL, BS 4800, BS 381 and Thermoguard Select available on request. Contact manufacturer and insert requirements.

Finish

Matt.

Satin.

Eggshell.

Application temperature

8–30°C.

Guidance for specification option:

  • Maximum relative Humidity below 75%.
  • Surface should be at least 3°C above the dew point. 

Composition

Catalytic and safe vapour-emission compounds.

Guidance for specification option:

Nano-particle encapsulation water-based polyurethane hardened cross-linking acrylic. 

Drying time

Touch dry (one hour); fully dry (four hours).

Flash point

93°C.

Density

1.3–1.4 g/ml.

pH

8>9.