NBS Source
I'm a manufacturer

Thermoguard Wallcoat Insulating Basecoat

Verified by manufacturer 15 days ago

Thermoguard UK Ltd

Insulating basecoat for wallcoat anti-microbial SFR smoke and flame retardant fire protection upgrade systems.

Jump to:
01142 768008 Website

Application

For use on wall and ceilings.

Description

Insulating basecoat for wallcoat anti-microbial SFR smoke and flame retardant fire protection upgrade systems for painted and multi-layer painter walls and ceilings. 


Features and benefits:

  • Available in can sizes of 25 m² and 50 m²
  • Compliant with BS EN 13501, B-s1,d0 spread of flame on walls and ceilings including surfaces coated with high risk multiple layers of paint.
  • Can be used as part of a system to achieve 30 or 60 minute fire resistance.
  • Good adhesion.
  • Permanent protection.
  • Tintable to undercoat shades.
  • Finished system make walls anti-viral and anti-bacterial - both with +90% efficacy.
  • Finished system forms a smooth aesthetically pleasing, durable finish resistant to repeated cleaning to internal walls and ceilings.
  • Once the works are complete the relevant certification can be applied for via the Thermoguard website.
  • Tested to UKAS and EOTA fire standards.


Application:

  •  All surfaces must be clean and dry. Remove all possible surface contaminates such as grease, smoke residues, silicates.
  • Can be brush and roller applied using woven fabric roller sleeves and synthetic bristle brushes or spray applied using a pressure pot and gun conventional unit with small compressor.
  • Apply one coat of Thermoguard Wallcoat Insulating Basecoat, to be overcoated with Wallcoat Anti-Microbial Smoke and Flame Retardant. 
  • Apply at rate stated on can or specification to protect surfaces and enable project certification. 

General information

Color

White

Finish

Smooth

Material

Water-based

Shape

Formless

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_35_31_68_29 Flame-retardant coatingsPrimary
Pr_35_31_68_40 Hygienic coatings

CAWS

M60/172 Flame-retardant coating system

M60/18 Special coating

M60/195 Special coating

M60/175 Protective coating

M60/19 Flame-retardant coatings

Specification data - Flame-retardant coatings

Reaction to fire rating (indicative)

To BS EN 13501, B-s1,d0.

Solvent

Water-based.

VOC content (maximum)

16 g/L.

Colour

White.

Finish

Smooth.

Application temperature

8–30°C.

Guidance for specification option:

  • Maximum relative Humidity below 75%.
  • Surface should be at least 3°C above the dew point. 

Composition

Catalytic powder.

Guidance for specification option:

Expansion agent, insulating char former, char hardeners and fibres Binder: fire protection adhesive grade rapid reaction acrylic resin. Water based.

Drying time

Touch dry (one hour); over paintable with Wallcoat Anti-Microbial SFR (four hours).

Density

1.32 g/ml.