Verified by manufacturer 13 days ago
Fire stopping between spandrel panel and roof covering
For installing between spandrel panel and roof coverings.
Compressed between the top of the spandrel panel and underside of the roof covering, creating a fire and thermal break.
Features and benefits:
Color | Orange |
Material | Rock fibre mineral wool |
Shape | Manufacturer guidanceU-shape. |
Length | 1200 mm |
Width | 200 mm |
Height | 150 mm |
Uniclass | |
CAWS | F30/18 Cavity closers F30/180 Cavity closers |
Fire performance | To BS EN 13501-1, Euroclass A1. |
Materials | Rock fibre mineral wool. |
ThermalConductivity | 0.037 W/mK. |
Dimensions | 150/200 x 55 x 100/90 x 1200 mm. Manufacturer guidanceSuits single 100 mm spandrel. |
Material | Rock fibre mineral wool |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
Revit 2017 | 1 | |
- | 1 |
Cavity Stop Sock
Fire Stop Slab - Smoke and Cavity barrier for masonry
Fire Stop Strip - Fire-rated void filler for masonry
Flexi-Closer - Thermal closer for window/ door reveals
Insulated DPC - Thermal cavity closer
Open State Cavity Barrier (OSCB) - Ventilated cavity barrier
Party Wall DPC - Cavity Barrier for Masonry Wall Junction
Rockfibre Insulated DPC - Fire-Rated Cavity Closer Window and Door
Soffit Slab - Mineral Wool fire stopping in the soffit
Spandrel Barrier - Fire stopping at party wall and spandrel