Verified by manufacturer 1 month ago
A bespoke triple-glazed glass roof system with slim profiles for maximum daylight influx.
The panels can be configured in multiple solutions by combining the various installation options with gable and corner solutions. The bespoke nature of the system enables the design of almost any roof light for public and commercial buildings. Also suitable for refurbishment projects of public and commercial buildings.
A bespoke glass system, with slim and shallow profiles for optimal daylight influx.
The glazing panels enable the creation of a wide range of roof light designs, from flush installations in a pitched roof to pyramids on a flat roof.
Features and benefits:
Color | Grey White Black |
Finish | Powder-coated Anodized |
Material | Aluminium Polyurethane |
Width | 256 mm Guidance for specification option: Minimum. 1200 mm Guidance for specification option: Maximum. |
Height | 250 mm Guidance for specification option: Minimum. 3500 mm Guidance for specification option: Maximum. |
Warranty description | Ten year Guidance for specification option: On modules and flashings Three year Guidance for specification option: On actuators and electrical components |
Uniclass | |
CAWS | L10/45 Rooflights L10/460 Rooflights L10/490 Roof ventilators |
Form | Triple glazing panel. |
Size | 2 m².Guidance for specification option: Maximum panel area. |
Product performance | |
Fire performance | |
Reaction to fire | To EN 13501-1 Class B, S1 d0. |
Whole window U-value | 1.8 W/m²K. |
Frame | |
Material | Aluminium. |
Finish | |
Coating | Anodized.Polyester powder coated. |
Colour | Not required.White RAL 9010.Black RAL 9005.Anthracite grey RAL 7016. |
Glazing or infill | |
Type | Toughened outer glass and laminated inner safety glass solution.Float outer glass and laminated inner safety glass solution. |
Construction | Triple glazed. |
Colour | Not required.White RAL 9010.Black RAL 9005.Anthracite grey RAL 7016. |
Coating | Not required.Low E coating.Sun 1.Guidance for specification option: light sun protection |
Integral kerb | Timber.Structural steel.Concrete. |
Operation | |
Type | HFC, Fixed.HVC, Smoke ventilation.HVC, Natural ventilation. |
Control | Not required.Chain actuator. |
Accessories | Not required.Control Unit (WUC 102, WCC 310/320).Control Switch (WSK 102/103).Rain and wind sensor set (WLA 330).Rain Sensor (WLA 331). |
Execution | Installation of framed rooflights. |
Width | Guidance for specification option: Width between 256—1200 mm insert requirements. |
Height | Guidance for specification option: Height between 250—3500 mm insert requirements. |
Country of product manufacture | Lithuania |
Material | Aluminium Polyurethane |