  • For sealing the overlapping seams and securing the terminated perimeter edges of illbruck Class A2 and Class A1 Reaction to Fire Breather Membranes and Vapour Barrier membranes to the structure.
  • ME355 FR Sealing Tape maintains the Class A2-s1,d0 Reaction to Fire when used with illbruck ME050 A2, W1, ME055 A1, W2 Breather Membranes or ME060 A2 Vapour Barrier Membrane.
  • Compatible with wood, painted wood, concrete, masonry, gypsum board, calcium silicate board, aluminium and steel.

Description

A UV, fire-resistant and repositionable self-adhesive sealing and joining tape.


Features and benefits:

  • Easily cut manually and without any tool.
  • Can be applied in slightly damp conditions.
  • Reinforced with glass fabric.
  • Distinctive on the market.

General information

Color

Silver

Finish

Reflective

Material

Glass Fibre

Foil

Aluminium

Shape

Formless

Length

25000 mm

Width

75 mm

10 mm

125 mm

Warranty description

Other

Guidance for specification option:

Any product which has been applied (a) in accordance with Tremco CPG UK Ltd written instructions and (b) in any applications recommended by Tremco CPG UK Ltd, but which is proved to be defective, will be replaced free of charge.

Uniclass

Pr_35_90_87_69 Polymer-based adhesive sealant tapesPrimary

Specification data - Polymer-based adhesive sealant tapes

Material

Glass fibre reinforced aluminium foil.

Bond

Reinforced high strength dispersion adhesive.

Fire performance

-

Reaction to fire

To BS EN 13501-1, Class A2-s1, d0.

Guidance for specification option:

When used with other illbruck Class A2 or better monolithic membranes.

Size

75 mm wide.

10 mm wide.

125 mm wide.

Colour

Silver.

Execution

-

Manufacturer guidance

As per manufacturers' Technical Data Sheet. Primer AT140 is required when bridging over known barriers to adhesion such as over-applied and smeared Fire Rated Silicone based sealants applied between horizontal and vertical butt joints in sheathing boards and at the head and foot of sheathing boards at the slab edge interface. Apply the tape wrinkle and bubble free, do not stretch the tape when applying. Apply in pre-cut short over lapping sections or continuously direct from the roll.

Application temperature

-10°C to +30°C.

Service temperature

-40° to +90°C.