Janus C4 Multi-Blade Controller is an access control system controller for use with Janus C4 host software, fitted with the OSDP blade developed to support up to 16 readers.
The Janus C4 Multi Controller with OSDP Blade is suitable for various settings, including:
The Janus C4 Multi-Blade Controller is an access control system controller for use with Janus C4 host software.
The OSDP blade is a plug-in module that works in the multi-Controller. Each OSDP Blade enables the connection of four OSDP readers and two doors in JanusC4 access control systems.
The multi-controller allows the connection of up to four blades which may be any combination of 2 Door Blades (Part No: JC4-ADV-BL-2D), each supporting two doors and two readers, OSDP Blades (Part No: JC4-ADV-BL-OSDP), each supporting two doors and four readers, or I/O Blades (Part No: JC4-ADV-BL-IO16), each supporting up to eight supervised inputs and eight volt-free relay outputs.
Open Supervised Device Protocol (OSDP) has been developed to provide enhanced security that older systems are not able to offer. As the only protocol that’s secure and open to communication between readers and controllers, it’s the preferred option for high-security environments.
The multi-controller has the capability to support the connection of up to 16 readers and 8 doors
Features and benefits:
Color | Black |
Finish | Other |
Material | Plastic |
Shape | Rectangle |
Length | 148 mm Guidance for specification option: Base unit only. 197 mm Guidance for specification option: With blades. |
Width | 205 mm |
Height | 38 mm Guidance for specification option: Base unit only. 65 mm Guidance for specification option: With blades. |
Warranty description | Five year |
Uniclass | |
CAWS | W90/130 Electronic access control system W90/363 Access control units |
Standards | To EN 55022:2010 Class B, EN 50130-4:2011 inc A1:2014 and IEC 62599-2:2010. |
Type of operation | Networked. |
Number of doors per controller | Up to eight. |
Number of users (minimum) | 200 000. |
Communication interface | Ethernet.Guidance for specification option: Ethernet 10/100 BASE-T. RS-485.Guidance for specification option: RS-485 2-wire 19.2 k baud. |
Visual indication | Status LEDs. |
Interfaces | |
Door lock relays | Up to eight. |
Door status monitoring | Up to eight. |
Readers | Up to eight. |
Request-to-exit buttons | Up to eight. |
Rated operational voltage (Ue) | 12 V.d.c.Power over ethernet (POE).Power over ethernet (POE)+. |
Rated operational current (In) | 300 mA (maximum). |
Data encryption | 256 bit.Guidance for specification option: AES-256 bit encryption. |
Battery backup | |
Battery location | Not required.External battery backup.Guidance for specification option:
|
Battery backup capacity | Not required.12 V lead-acid battery up to 7 Ah capacity.Guidance for specification option: Optional. |
Storage memory capacity | 256 MB on-board memory. |
Control features | |
Anti-passback | Anti-passback supported. |
Enclosure | |
Material and finish | Plastic. |
Colour | Black. |
Accessories | USB port.Guidance for specification option: Two USB 2.0 Type A ports; intended for Grosvenor-approved products only. Can be used to update controller firmware. |
Controller | Multi-blade controller. |
Blade | OSDP Blade. |
Enclosure | Grosvenor enclosure (ADV-ENC). Other. Guidance for specification option: Insert requirements. |
Security | Optical tamper (Grosvenor enclosure only). External tamper switch (volt-free). |
Operating temperature | 0°C to +49°C. |
Humidity | 5–85±5% at 30±2°C. |
Weight | 0.285 kg. |
Dimensions | Base unit only: 205 x 148 x 38 mm. |
Material | Plastic |