Verified by manufacturer 1 day ago
Fire rated sealing membrane for doors and windows.
Suitable for use in windows and doorway applications, and in join sealing between sheathing boards and the main structure in horizontal and vertical applications.
FR Window & Door Sealing Membrane HD (ME007) is a Class B, permanently UV resistant, high strength polyester, airtight and fully watertight membrane used as a perimeter membrane seal to the external side of glazed units such as windows and doors.
Features and benefits:
Color | Black |
Finish | Unfinished |
Material | Polyester |
Shape | Rectangle |
Length | 50000 mm |
Width | 60 mm 100 mm 150 mm 200 mm 250 mm |
Height | 0.4 mm |
Warranty description | Lifetime |
Uniclass | |
CAWS | L20/80 Sealant joints L20/820 Sealant joints P10/65 Breather membrane L10/810 Sealant joints H92/785 Breather membrane P10/320 Breather membrane L10/75 Sealant joints |
SKU Code | ME007 |
Classification data | |
Class (minimum) | W1. |
Performance criteria | |
Water vapour properties | To EN ISO 12572, <0.6 MN/g. Guidance for specification option:
|
Fire performance | To BS EN 13501-1, Class B-s2, d0. Guidance for specification option: When installed directly over a mineral substrate with a fire Classification of A1 or A2-s1, d0 and a density ≥652.5 kg/m³ bonded with SP025, with or without illbruck AT140 primer. |
Tensile properties | Longitudinal direction: >300 N/50 mm. Transverse direction: >200 N/50 mm. Guidance for specification option:
|
Environmental performance requirements | |
Environmental rating | EC1+. |
Material | Polyester. |
Weight (minimum) | 210 g/m². |
Thickness (minimum) | 0.4 mm. |
Dimensions | 50 m x 60 mm. 50 m x 100 mm. 50 m x 150 mm. 50 m x 200 mm. 50 m x 250 mm. 50 m x 300 mm. 50 m x 350 mm. 50 m x 400 mm. Manufacturer guidanceRoll length x width. |
Tear resistance | Longitudinal direction: >120 N. Transverse direction: >120 N. |
Weather resistance | To EN 12208, Class AE2400, ≥2400 Pa. Manufacturer guidanceDriving rain resistance. |
Air permeability | To BS 6375-1, Class 4 (600 Pa). Guidance for specification option:
|
UV resistance | To EN 1296 and EN 1297, 12 months (exposed) and permanent (covered). |
Service temperature | -40°C to 150°C. |
Elongation | Longitudinal direction: <25%. Transverse direction: <25%. |
Material | Polyester |