Verified by manufacturer 1 month ago
Standard roll width: 2.7 m
Four-layer laminate, class W1 water-resistant and reflective wall breather.
Suitable for wall applications, and use on timber frame and offsite/ modular constructions.
A high quality, four-layer laminate, class W1 water-resistant wall breather membrane, for insulated wall applications.
To maximize the products performance the reflective face is unbranded, with no text or images, and is white on the reverse.
Features and benefits:
Color | Silver Guidance for specification option: Reflective. White Guidance for specification option: Metallic. |
Finish | Reflective |
Material | Polypropylene Guidance for specification option: Breathable microporous film. |
Shape | Rectangle |
Length | 50000 mm 100000 mm |
Width | 1500 mm 2700 mm |
Warranty description | Lifetime |
Uniclass | |
CAWS | H92/785 Breather membrane H31/55 Breather membrane H30/50 Breather membrane H22/20 Breather membrane H21/20 Breather membrane P10/320 Breather membrane H31/280 Breather membrane H30/350 Breather membrane H22/130 Breather membrane H21/130 Breather membrane |
Standard | To BS EN 13859-2. |
Performance criteria | |
Water vapour properties | To BS EN ISO 12572, 0.08 m. |
Fire performance | To BS EN 13501-1, Class E.Guidance for specification option: Fire class tested on chipboard according to EN 13238. |
Tensile properties | Tensile strength to BS EN 12311-1, MD/CD: 200/ 110 N/50 mm. |
Class (minimum) | W1.Manufacturer guidanceResistance to water penetration to EN 1928. |
Recycled content | 0%. |
Material | Polypropylene. |
Form | Microporous. |
Weight (minimum) | 118 g/m².Guidance for specification option: Nominal. |
Reflective face | To EN 15976, 98%. |
Roll weight | 33 kg. |
Roll length | 100 m. |
Roll width | 2.7 m. |
Elongation MD/CD | To EN 12311-1, MD/CD: 75/90%. |
Tear resistance MD/CD | To EN 12310-1, MD/CD: 80/110 N. |
Resistance to air penetration | To EN 12114, 0.000 m³/m³h.50.pa. |
Temperature resistance | -40°C to 80°C. |
Emissivity | 0.02 Ɛ. |
Tape | Not required. Novia® Double Sided Lap Tape (DSLT). Novia® Reflective |
Air and vapour control layer | Novia® VC200 Reflective. Novia® VariCheck FR. Manufacturer guidanceEnsure that a Novia air and vapour control layer, is installed on the warm side of the insulation to limit unwanted interstitial condensation. As little as 1–3% moisture contamination within the insulation can adversely affect the achieved thermal performance by more than 30%. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | Europe |
Material | Polypropylene Guidance for specification option: Breathable microporous film. |
Aluthermo RoofReflex® - Insulated Breather Underlay Membrane
Novia Black + Pro Breather Membrane - Roof and wall breather membrane
Novia Black + Supreme Breather Membrane - Roof and Wall Breather Membrane
Novia Black+ Construction Wrap - Breather membrane
Novia Black+ Ultra Roof & Wall Breather Membrane
Novia Building Wrap Wall Breather - Breather Membrane
Novia FR Class B‐s1,d0 fire rated Breather Membrane
Novia Reflex Reflective Breather Membrane
Novia UV Facade FR B-s1,d0 fire rated Breather Membrane