Verified by manufacturer 4 months ago
BM Trada
Certificate type
Fire-rated glass doorset, non-rebated offering 60 minutes insulation and 60 minutes integrity
For use in conjunction with Technishield 65 partition system.
A framed, double-leaf, non-rebated, fire-rated glass doorset on hinges.
Features and benefits:
Color | Silver White Other |
Finish | Powder-coated |
Material | Glass |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Three year |
Uniclass | |
CAWS | L20/480 Doorsets L20/55 Doorsets |
Product range |
System performance | Fire performance. |
Doorset | |
Type | Fire rated glass doorset. |
Seals or inserts | |
Door | Manufacturer's standard.Guidance for specification option: Dropseal: Type RO drop seals. Door seals: Fire and smoke protection double seal. |
Over panels | Not required.Over panel.Over panel and side panel.Guidance for specification option: Insert requirements. |
Side panels | Not required.Side panel both sides.Side panel left side.Side panel right side.Over panel and side panel.Guidance for specification option: Insert requirements. |
Hardware | Manufacturer's standard.Guidance for specification option: Hinges: Two face-fitted, weld-on hinges per leaf. Handles: Forster stainless steel cranked pull handles. Lock: Not applicable. Euro cylinder: Not applicable. Door closer: TS-93 2-4. Other.Guidance for specification option: Insert requirements; contact manufacturer for information. |
Samples required | Not required.Required. |
Finish/ Colour | Powder-coated, RAL. Guidance for specification option: Insert requirement; contact manufacturer for more information. Powder-coated, RAL 9006 Silver. Guidance for specification option: 50 microns, 30% gloss (nominal). Powder-coated, RAL 9010 White. Guidance for specification option: 50 microns, 30% gloss (nominal). |
Manifestation | Guidance for specification option: Insert requirements. |
Fire rating | E60 – 60 minutes' integrity and insulation (60/60). |
Size | Guidance for specification option:
|
Configuration | As shedule. As drawing. Guidance for specification option: Insert drawing reference number. |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 179 kg CO₂ eq/m² Self declared Guidance for specification option: See Environmental Product Declaration literature for LCA data. |
Platform | Compatible | Version |
---|---|---|
- | 1 |
Technishield 50 Double Door
Technishield 50 Non-rebated, fire-rated double glazed door 30/0 or 60/0
Technishield 50 rebated fire rated single glazed door 30/0 or 60/0
Technishield 65 EI30 Single Door
Technishield 65 EI60 Double Door
Technishield 65 non-rebated fire-rated double glazed door 30/30
Technishield 65 rebated fire rated single leaf door 60/60
Technishield 65 rebated fire-rated double glazed door 30/30
Technishield 70 rebated fire-rated double leaf door 90/90
Technishield 70 rebated fire-rated single leaf door 90/ 90