60/60 fire-rated glass doorset, rebated single door.
For use in conjunction with Technishield 65 partition system.
A framed, rebated, single-leaf, fire-rated glass doorset on hinges, for use in conjunction with Technishield 65 partition system, offering 60 minutes' integrity and insulation. Part M-compliant clear opening included.
Finish | Powder-coated |
Material | Glass |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Manufacturer guidanceSee standard warranty document. |
Uniclass | |
CAWS | L20/480 Doorsets L20/55 Doorsets |
Product range |
System performance | Fire performance. |
Doorset | |
Type | Fire rated glass doorset. |
Seals or inserts | |
Door | Manufacturer's standard.Guidance for specification option: Dropseal: Type RO drop seals. Door seals: Fire protection double seal. |
Over panels | Not required.Over panel.Over panel and side panel.Guidance for specification option: Insert requirements. |
Side panels | Not required.Side panel both sides.Side panel left side.Side panel right side.Over panel and side panel.Guidance for specification option: Insert requirements. |
Hardware | Manufacturer's standard.Guidance for specification option: Hinges: Three face fitted weld-on hinges. Handles: Forster stainless steel lever handle set, fire-rated, cranked U-form steel cored with 9 mm spindle. Lock: Two-point fire-rated lever latch with Euro-cylinder operated deadlock. Euro cylinder: Cylinder and turn – 35 mm/ 35 mm. Door closer: TS-93 2-4. Other.Guidance for specification option: Insert requirements; contact manufacturer for information. |
Samples required | Not required.Required. |
Finish/ Colour | Powder-coated, RAL. Guidance for specification option: Insert requirement; contact manufacturer for more information. Powder-coated, RAL 9006 Silver. Guidance for specification option: 50 microns, 30% gloss (nominal). Powder-coated, RAL 9010 White. Guidance for specification option: 50 microns, 30% gloss (nominal). |
Manifestation | Guidance for specification option: Insert requirements. |
Size | Guidance for specification option:
|
Fire rating | EI60 – 60 minutes' integrity and insulation (60/60). |
Configuration | As schedule. As drawing. Guidance for specification option: Insert drawing reference number. |
Country of material origin | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 179 kg CO₂ eq/m² Self declared |
Platform | Compatible | Version |
---|---|---|
- | 1 |