Verified by manufacturer 7 months ago
High-performance waterproof membrane
Vertical Surfaces: Maxiprufe Plus should be pre-applied to the inside face of the shuttering to be subsequently filled with concrete. The sheets should be installed with the textile in contact with the freshly placed concrete and lined vertically ensuring that all lap joints face away from the concrete pour.
Adjacent sheets of membrane should be lapped by 100 mm. Horizontal Surfaces: Maxiprufe Plus should be laid with the textile facing the installer and in direct contact with concrete. Adjacent sheets should be lapped by a minimum of 100 mm and the lap joint should be staggered by 300 mm to avoid four sheets lapping at one location.
Maxiprufe Plus is a composite pre-applied waterproof membrane utilizing the very latest PREMCRETE APANTM technology which produces an enhanced active bond to fresh concrete to become an internal part of the structure to which it has been applied.
The active pre-applied nano seal technology provides a secondary waterproof element for unique hybrid protection. The self-healing nature of the membranes secures the integrity of the waterproofing system, substantially reducing the risk of failure.
Color | Red |
Finish | Semi-gloss |
Material | Polyethylene |
Shape | Rectangle |
Length | 2000 mm |
Width | 2500 mm |
Height | 2000 mm |
Warranty description | 25 year |
Uniclass | |
CAWS | J10/120 Cement: sand mortar with proprietary waterproof admixture J40/120 Loose-laid plastics or rubber sheet damp-proofing J40/20 Loose-laid plastics or rubber sheet damp-proofing J40/297 Waterproofing/ damp-proofing/ gas-retardant membrane J44/120 Geosynthetic clay lining (GCL) |
Product range |
Material | Polyethylene. |
Third-party certification | BDA Agrement BAB 17-061/01/A. |
Performance characteristics | |
Tear resistance | MD: 560 N; CD: 515 N (to DIN EN 12310-1). |
Elongation to break | MD: 90%; CD: 80% (to DIN EN ISO 12311-2). |
Form | Micro-perforated (Needle punched). |
Physical properties | |
Colour | White. |
Weight (minimum) | 530 g/m². |
Dimensions | |
Thickness (minimum) | 3 mm. |
Width (minimum) | 2 m. |
Roll length (minimum) | 50 m. |
Watertightness | Pass (to DIN EN 1928 B). |
Water vapour transmission | 8.25 x 10^-9 kg/m^-2/sec^-1. |
Country of material origin | United Kingdom |