A fully adhered, single ply EPDM warm roof system.

Jump to:
+44 (0)1565 756186 Website

Application

  • Suitable for contoured roofs, roofs with irregular shape and any roof with limited load bearing capacity, provided the substrate is compatible with Elevate contact adhesives.
  • Suited for green roofs and roofs with PV installations.

Description

The RubberGard™ EPDM Fully Adhered System is a lightweight system with design flexibility. The membrane is fully adhered directly to the substrate using Elevate bonding adhesive.


Features and benefits:

  • Suitable for unusual roof configurations
  • Lightweight system.
  • Fast coverage.
  • Aesthetics.
  • High wind uplift performance.


System components:

  • RubberGard™ EPDM LSFR.
  • BA-2012 Bonding Adhesive.
  • BA-2004(T) Bonding Adhesive.
  • ISOGARD™ HD Cover Board.
  • DensDeck® Prime Cover Board.
  • RESISTA™ MG PIR Insulation.
  • ISOGARD™AK PIR Insulation.
  • ISOGARD™ MG PIR Insulation.
  • I.S.O. Twin Pack Insulation Adhesive.
  • V-Gard™ Vapor Control layer.
  • SA-19 Primer.

General information

Color

Black

Finish

Smooth

Material

Rubber

Polyisocyanurate (PIR)

Shape

Rectangle

Length

30500 mm

Width

3050 mm

5080 mm

Manufacturer guidance

Specifically designed for best compatibility in fully adhered systems and have no folds.

Height

1.1 mm

1.5 mm

Warranty description

Ten year

15 year

20 year

Uniclass

Ss_30_40_30_80 Single layer sheet warm roof covering systemsPrimary

CAWS

J42/10 Warm deck roof covering

J42/110 Warm deck roof covering

Specification data - Single layer sheet warm roof covering systems

Preparation

-

Horizontal work

SA-19 Primer.

Guidance for specification option:

The substrate will be securely fixed, clean, dry, smooth and free of contaminants such as greases, animal fats, coal tar and oil-based products. All sharp edges, nibs and rough surfaces which could damage the membrane will be removed or otherwise isolated. Should the V-Gard MAX air and vapour control layer be used, the substrate will be prepared with Elevate SA-19 Primer.

Air and vapour control layer

-

Type

Elevate V-Gard MAX Self-Adhesive Air & Vapour Control layer.

Guidance for specification option:

Use where insulation layer is to be adhered to the AVCL.

Self-adhesive to approved substrates (wood, steel).

Elevate V-Gard ALU1500 Self-Adhesive Air & Vapour Control layer.

Guidance for specification option:

Use where insulation layer is to be mechanically attached through the AVCL.

Self-adhesive to approved substrates (wood, steel).

Elevate V-Gard PE 200 Air & Vapour Control layer.

Guidance for specification option:

Use where insulation layer is to be mechanically attached through the AVCL (Low Humidity Class Buildings Only).

Loose laid over the approved substrate, joints are taped using V-Gard PE Seam Tape.

Elevate V-Gard PE 200 E Air & Vapour Control layer.

Guidance for specification option:

Use where insulation layer is to be mechanically attached through the AVCL (Low Humidity Class Buildings Only).

Loose laid over the approved substrate, joints are taped using V-Gard PE Seam Tape.

Elevate V-Gard PE 400 Air & Vapour Control layer.

Guidance for specification option:

Use where insulation layer is to be mechanically attached through the AVCL (Low Humidity Class Buildings Only).

Loose laid over the approved substrate, joints are taped using V-Gard PE Seam Tape.

Attachment

As Type.

Guidance for specification option:

See Type guidance above for details.

Insulation

-

Type

ISOGARD AK PIR Insulation.

Guidance for specification option:

Thermal conductivity: 0.023 W/m.K.

Thickness: 30–160 mm. Insert requirements.


Elevate ISOGARD AK insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gastight multi-layered aluminium complex.

ISOGARD MG PIR Insulation.

Guidance for specification option:

Thermal conductivity: 0.025–0.028 W/m.K.

Thickness: 30–160 mm. Insert requirements.


Elevate ISOGARD MG insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gasopen mineral glassfibre facer.

RESISTA AK PIR Insulation.

Guidance for specification option:

Thermal conductivity: 0.023 W/m.K.

Thickness: 30–160 mm. Insert requirements.


RESISTA AK PIR insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gastight multi-layered aluminium complex.

RESISTA MG PIR Insulation.

Guidance for specification option:

Thermal conductivity: 0.025–0.028 W/m.K.

Thickness: 30–160 mm. Insert requirements.


RESISTA MG PIR insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gasopen mineral glassfibre facer.

ISOGARD HD cover board.

Guidance for specification option:

An optional, lightweight, high-density polyiso (PIR) foam cover board of 12.7 mm thickness, with coated fiberglass facers to both sides, which is used to protect the insulation layer beneath and may also be used as a recovery board. It provides an optimum surface for fully adhered Elevate roofing membranes.

Manufacturer guidance

Consult the manufacturer's Technical Services Department for R-Value/U-value calculations as required.

Attachment

I.S.O. Twin Pack Insulation Adhesive.

Guidance for specification option:

Elevate I.S.O. Twin Pack Insulation Adhesive is a two-component low-rise polyurethane adhesive designed for anchoring acceptable roof insulation and cover boards to an acceptable substrate, as well as for adhering multiple layers of insulation. It is a solvent-free insulation adhesive that contains no harmful HCFC or CFC.

Waterproof covering

-

Type

RubberGard™ EPDM LSFR Roofing Membrane 1.1 mm.

Guidance for specification option:

1.1 mm thickness is recommended for general roofing applications where access and foot traffic is infrequent.

RubberGard™ EPDM LSFR Roofing Membrane 1.5 mm.

Guidance for specification option:

1.5 mm thickness is recommended for roofs requiring higher levels of foot traffic, green roofs, blue roofs, PV roofs etc.

Manufacturer guidance

100% cured non-reinforced, Ethylene-Propylene-Diene Terpolymer (EPDM) synthetic rubber, manufactured in an ISO 9001 and ISO 14001 registered facility. Minimum unspliced width of 3.05 m.

Specification compliance:

UL Classified/ FM Approved.

ASTM D 4637/ EN 13956 (CE Mark).

7500 hrs of Artificial Ageing as per EN 1297.

Attachment

BA-2012 Bonding Adhesive.

BA-2004(T) Bonding Adhesive.

Manufacturer guidance

Super spreader or roller applied contact adhesives.

Contact the manufacturer's Technical Department for details on defining the proper method of attachment for the substrate.

Joints

100 mm minimum overlap with 76 mm QuickSeam Splice Tape.

Surface protection

QuickSeam Walkway Pads.

Guidance for specification option:

760 x 760 mm high quality rubber pads with QuickSeam Tape factory laminated to the bottom. They are used for protection of the Elevate RubberGard EPDM membrane in areas of regular roof traffic (periodical maintenance around mechanical equipment, access doors, etc.).

System accessories

QuickSeam Splice Tape.

QuickSeam FormFlash.

QuickSeam Flashing.

QuickSeam SA Flashing.

QuickSeam Reinforced Perimeter Fastening Strip.

QuickSeam Universal Pipe Flashing.

QuickSeam Conduit Flashing.

QuickSeam Penetration Pocket.

QuickSeam Walkway Pad.

QuickPrime Plus.

Lap Sealant HS.

All Purpose (AP) Fasteners.

Heavy Duty (HD) Fasteners.

Splice Wash (SW-100).

Cleaner C-20.

Water-Block Seal (S-20).

Pourable Sealer S-10 (Parts A & B).

Coiled Metal Batten Strip.

Metal Batten Strip.

Termination Bar.

V-Plates.

Corners

QuickSeam FormFlash.

Guidance for specification option:

Used to form internal and external corners.

RubberGard EPDM membrane.

Guidance for specification option:

As an option on low upstands, internal corners may also be achieved by folding and adhering the RubberGard EPDM membrane to the upstand.

Pipes

Pipe penetrations: QuickSeam FormFlash.

Pipe penetrations: QuickSeam Universal Pipe Flashing and Conduit Flashing.

Outlets

Drains: Install Water Block Seal (S-20) between membrane and outlet bowl. Secure membrane mechanically to outlet using integral clamping ring.

Drains: Insert outlet bedded on Water Block Seal (S-20). Secure and flash with QuickSeam FormFlash or SA Flashing.

Walls

Wall terminations: Termination bar, fastened with Water Block Seal (S-20) and Lap Sealant HS installed along top edge.

Guidance for specification option:

@200 mm (maximum) o.c.

Wall terminations: Metal batten bar fastened with surface mounted or inserted metal counter flashing protection.

Guidance for specification option:

@150 mm (maximum) o.c.

Wall terminations: Metal capping or concrete coping stones.

Wall termination: Preformed metal edge trim.

Guidance for specification option:

An appropriate metal edge trim will be prefabricated and installed with fasteners @ max. 100 mm centers. The edge trim will be sealed with QuickSeam Flashing.

Sustainability data

Material

Rubber

Polyisocyanurate (PIR)

Recyclability

An Environmental Product Declaration (EPD) is available upon request.

Third party certifications

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Elevate RubberGard EPDM Systems

EPD

EPD

Non-Reinforced EPDM

Literature

RubberGard™ EPDM

RubberGard™ EPDM

Similar products from Elevate EMEA

Rhenofol® PVC-P Mechanically Attached Warm Roof System - Single Ply PVC-P Warm Roof System

Rhenofol® PVC-P Mechanically Attached Warm Roof System - Single Ply PVC-P Warm Roof System

RubberGard™ EPDM Ballasted Warm Roof System

RubberGard™ EPDM Ballasted Warm Roof System

RubberGard™ EPDM Inverted Warm Roof System

RubberGard™ EPDM Inverted Warm Roof System

RubberGard™ EPDM Mechanically Attached Warm Roof System

RubberGard™ EPDM Mechanically Attached Warm Roof System

RubberGard™ EPDM SA Fully Adhered Warm Roof System - Self-adhesive EPDM Single Ply Roofing

RubberGard™ EPDM SA Fully Adhered Warm Roof System - Self-adhesive EPDM Single Ply Roofing

UltraPly™ TPO  Inverted Warm Roof System

UltraPly™ TPO Inverted Warm Roof System

UltraPly™ TPO Ballasted Warm Roof System

UltraPly™ TPO Ballasted Warm Roof System

UltraPly™ TPO Fully Adhered Warm Roof System

UltraPly™ TPO Fully Adhered Warm Roof System

UltraPly™ TPO Mechanically Attached Warm Roof System  - Single Ply Membrane Warm Roof System

UltraPly™ TPO Mechanically Attached Warm Roof System - Single Ply Membrane Warm Roof System