Verified by manufacturer 23 days ago
EPD
Certificate type
Self-adhesive EPDM single ply roofing system.
Warm roof system for flat roofs featuring a self-adhesive RubberGard™ EPDM single ply roof membrane.
RubberGard™ EPDM SA represents the next generation of self-adhered roofing membranes. It features a factory-applied Secure Bond adhesive across the underside of the membrane, which eliminates the need for bonding adhesives or waiting time. Consequently, RubberGard™ EPDM SA can be installed much faster than standard EPDM roofing membranes, so more roof area can be covered in a day and more roofs can be completed in the season.
RubberGard™ EPDM SA is based on Elevate’s highly durable RubberGard™ EPDM roofing membrane, together with its unique Secure Bond technology, which ensures the uniform and strong adhesion of the membrane to the substrate. This makes RubberGard™ EPDM SA even easier to install, reliable and pleasant to work with.
Features and benefits:
Color | Black |
Finish | Smooth |
Material | EPDM |
Shape | Rectangle |
Length | 30000 mm |
Width | 3000 mm |
Height | 1.5 mm |
Warranty description | 20 year |
Uniclass | |
CAWS | J42/10 Warm deck roof covering J42/110 Warm deck roof covering |
Preparation | |
Horizontal work | The substrate will be securely fixed, clean, dry, smooth and free of contaminants such as greases, animal fats, coal tar and oil-based products. All sharp edges, nibs and rough surfaces which could damage the membrane will be removed or otherwise isolated. |
Skirtings and vertical work | SA-19 Primer.Guidance for specification option: Elevate SA-19 Primer is used to prime and prepare exterior concrete, wood, and metal surfaces to enhance the adhesion of Elevate V-Gard vapour control. It is also used to prime seams of the V-Gard vapour control layer when required. Can also be used for vertical application of the RubberGard EPDM SA membrane. QuickPrime Plus.Guidance for specification option: Alternative primer for vertical application of the RubberGard EPDM SA membrane. |
Air and vapour control layer | |
Type | Elevate V-Gard MAX Self-Adhesive Air & Vapour Control layer.Guidance for specification option: Use where insulation layer is to be adhered to the AVCL. Self-adhesive to approved substrates (wood, steel). Elevate V-Gard ALU1500 Self-Adhesive Air & Vapour Control layer.Guidance for specification option: Use where insulation layer is to be mechanically attached through the AVCL. Self-adhesive to approved substrates (wood, steel). Elevate V-Gard PE 200 Air & Vapour Control layer.Guidance for specification option: Use where insulation layer is to be mechanically attached through the AVCL (Low Humidity Class Buildings Only). Loose laid over the approved substrate, joints are taped using V-Gard PE Seam Tape. Elevate V-Gard PE 200 E Air & Vapour Control layer.Guidance for specification option: Use where insulation layer is to be mechanically attached through the AVCL (Low Humidity Class Buildings Only). Loose laid over the approved substrate, joints are taped using V-Gard PE Seam Tape. Elevate V-Gard PE 400 Air & Vapour Control layer.Guidance for specification option: Use where insulation layer is to be mechanically attached through the AVCL (Low Humidity Class Buildings Only). Loose laid over the approved substrate, joints are taped using V-Gard PE Seam Tape. |
Attachment | As Type.Guidance for specification option: See Type guidance above for details. |
Insulation | |
Type | RESISTA™ AK+/MG insulation boards.Guidance for specification option: Consult manufacturer for details. ISOGARD™ AK/MG insulation boards.Guidance for specification option: Consult manufacturer for details. ISOGARD HD cover board.Guidance for specification option: An optional, lightweight, high-density polyiso (PIR) foam cover board of 12.7 mm thickness, with coated fiberglass facers to both sides, which is used to protect the insulation layer beneath and may also be used as a recovery board. It provides an optimum surface for fully adhered Elevate roofing membranes. Consult manufacturer for further details. DensDeck Prime cover board.Guidance for specification option: Patented design that consists of a water- and moisture-resistant treated gypsum core laminated on both sides to a mat glass facer. Features a pre-primed surface for a better bond in case of a fully adhered roof cover. Consult manufacturer for further details. Other.Guidance for specification option: Insert details of suitable PIR MG insulation boards (consult manufacturer to confirm suitability. |
Attachment | I.S.O. Twin Pack Insulation Adhesive.Guidance for specification option: Elevate I.S.O. Twin Pack Insulation Adhesive is a two-component low-rise polyurethane adhesive designed for anchoring acceptable roof insulation and cover boards to an acceptable substrate, as well as for adhering multiple layers of insulation. It is a solvent-free insulation adhesive that contains no harmful HCFCs or CFCs. Mechanical attachment using appropriate fasteners and load spreading plates as approved by manufacturer.Guidance for specification option: Consult manufacturer for details. |
Waterproof covering | |
Type | RubberGard™ EPDM SA.Guidance for specification option: 1.5 mm thick; supplied as standard in rolls of 30 x 3 m. |
Attachment | Self-adhesive. |
Joints | Side laps 100 mm minimum overlap with 76 mm QuickSeam Splice Tape. |
Accessories | QuickSeam Splice Tape.QuickSeam FormFlash.QuickSeam Flashing.QuickSeam SA Flashing.QuickSeam Reinforced Perimeter Fastening Strip.QuickSeam Universal Pipe Flashing.QuickSeam Conduit Flashing.QuickSeam Penetration Pocket.QuickSeam Walkway Pad.QuickPrime Plus.Lap Sealant HS.All Purpose (AP) Fasteners.Heavy Duty (HD) Fasteners.Splice Wash (SW-100).Cleaner C-20.Water-Block Seal (S-20).Pourable Sealer S-10 (Parts A & B).Coiled Metal Batten Strip.Metal Batten Strip.Termination Bar.V-Plates. |
Corners | QuickSeam FormFlash. Guidance for specification option: Used to form internal and external corners. RubberGard EPDM membrane. Guidance for specification option: As an option on low upstands, internal corners may also be achieved by folding and adhering the RubberGard EPDM membrane to the upstand. |
Pipes | Pipe penetrations: QuickSeam FormFlash. Pipe penetrations: QuickSeam Universal Pipe Flashing and Conduit Flashing. Manufacturer guidancePipe penetrations: All circular and odd-shaped roof penetrations passing through the membrane should be flashed using one of the following techniques, as described in the RubberGard EPDM Technical Guidelines:
|
Outlets | Drains: Install Water Block Seal (S-20) between membrane and outlet bowl. Secure membrane mechanically to outlet using integral clamping ring. Guidance for specification option: Consult manufacturer for details. Drains: Insert outlet bedded on Water Block Seal (S-20). Secure and flash with QuickSeam FormFlash or SA Flashing. Manufacturer guidanceDrains and scuppers are to be waterproofed with the usual RubberGard EPDM accessories, as per the RubberGard EPDM Technical Guidelines. |
Walls | Wall terminations: Termination bar, fastened with Water Block Seal (S-20) and Lap Sealant HS installed along top edge. Wall terminations: Metal batten bar fastened with surface mounted or inserted metal counter flashing protection. Wall terminations: Metal capping or concrete coping stones. Wall termination: Preformed metal edge trim. Manufacturer guidanceA roof edge or wall termination detail should be installed as specified by the designer and is applicable at all locations where the EPDM flashing ends, e.g. at all flat edges, wall or curb upstands. The standard roof edge details illustrated in the RubberGard EPDM Technical Guidelines are also applicable for the RubberGard EPDM SA system. The RubberGard EPDM SA flashing should always be mechanically fixed where ended, when used to flash in roof edges or wall termination, as per standard RubberGard EPDM detail drawings. |
Country of material origin | United States |
Country of product manufacture | United States |
Material | EPDM |
Recyclability | An Environmental Product Declaration is available upon request |